8 STANDAR OPERATOR
MAINTENANCE
_
__________________________
_
_
_________________________________________________________________
Please dispose of the used engine oil in a manner that is compatible
with the environment. We suggest you take it in a sealed container
to your local service station for reclamation. Do not throw it in the
trash, pour it on the ground or down a drain.
Welding
Welding must be carried out by authorized personnel, only, since some electrical devices have to
be disconnected during these operations..
8.2 Battery recharging
Connect the feeding cable by means of the suitable plug 220V blue 110V yellow
Connect the red plug to battery charge plug ( fig. 4 )
For the batteries to recharge, it isn’t necessary that the machine is started or that the battery
sw itch is on the ON position. When the connection is done, the battery charger fan starts
When recharging the batteries, place the machine in a w ell-aired place in order to avoid
explosions due to the explosive gases generated by the batteries
The battery charger starts and stops automatically
It is recommended to avoid run the batteries completely down
otherwise the recharging time would remarkably extended thus
implying the risk of damaging the batteries. Once the machine is
stabilized, connect it to the power supply as soon as possible and
operate under voltage.
At the end of the working day or when the machine will be laid up for
long periods, remember to disconnect the battery switch in order to
avoid run the batteries completely down.
Battery charger
To avoid overheating, check that all the cooling clefts are not clogged.
Protect the battery charger from possible w ater sprays.
Make sure that the available pow er supply corresponds to that indicated on the battery
charger identification plate.
If an extension or a multiple jack are used, make sure they are suitable to the overall
voltage required.
Turn off the pow er supply before connecting or disconnecting plugs.
In case of lead-acid storage battery charging WARNINGN!!!:EXPLOSIVE GASES >
keep flames and sparks aw ay. Battery must be located on a ventilated area.
Do not use the battery charger to charge batteries of hot-air engine cars.
Only rechargeable batteries can be charged.
Check battery voltage is the same indicated on battery charger identification plate
Don't try to repair the battery charger: the cover opening may cause danger of electrical
shock
If the battery charge does not w ork correctly, unplug it immediately from the main and
from the battery and apply to the seller.