Chapter - Routine Maintenance
Page Issue 01
OG
6:14
V Range 501 651 801 - Operator’s Guide
Pneumatic Filter Regulator Unit
The filter regulator unit comprises a combined air filter and pressure
regulator.
The air is isolated and drained by turning the red gate valve on the
unit.
The air filter features an automatic drain.
MO2OG-003
10mm
max
C
B
A
Hydraulic Reservoir
CheckingOilLevel
Raise the body and engage the body prop (A)
in its highest position. The level (B) should be
10mm above the lower red line (C) on the gauge.
It is important that the correct level is maintained
as under filling can adversely affect the heat
dissipation rate of the oil, whilst over filling can
cause oil to overflow when the body is lowered.
The recommended oil is shown in the lubrication
chart at the end of this chapter.
Air Cleaner Restriction Indicator
A filter condition is electronically monitored and when restricted
the icon is displayed on the JVM, giving a positive indication of
when the air cleaner element needs replacing and so eliminates
haphazard servicing. It should be attended to immediately.
Note:
The indicator does not show the amount of dust present in the dust
cap. When the air cleaner requires servicing the warning icon will
be illuminated. After servicing the indicator will automatically reset.
Air Cleaner
The air cleaner elements must be replaced at the intervals given
in the Maintenance Schedule or if the filter restriction indicator is
showing red between these scheduled services.
To access the air cleaner elements, lift the retaining clips (A) and
remove the lid (B).
Remove the main filter element (C) by first pushing the filter down
and tilting it towards the radiator and then lift it out. There is a small
safety element (D) within the main filter body, this should be replaced
every third time the main element is changed. Re-assemble the air
cleaner ensuring all parts are correctly positioned and fitted.
Ensure that the elements, lid and clips are correctly fitted and that
the air intake pipe and clips to the engine are in good condition and
fully sealed.
M02OG-010
A
C
B
D
A
M02OG-051
VT - Twin Engine only
All Copyright and rights are the property of Johnston Sweepers Ltd