23
10. Others
10.1 Maintenance
Check whether the gate operates normally every month.
For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular
inspection is required as well.
Before installation and operation of the gate opener, please read all instructions carefully.
We reserve the right to change the instruction without prior notice.
10.2 Troubleshooting
Problems
Possible Reasons
Solutions
The gate cannot open or close
normally, and Display does not
light.
1.The power is off.
2.Fuse is burned.
3.Control board power wiring with
problem.
1.Switch on the power supply.
2.Check the fuse, change the fuse if burnt.
3.Re wiring according to instructions.
The gate can open but cannot
close.
1.Photocell wiring with problem.
2.Photocell mounting with problem.
3.Photocell is blocked by objects.
4.Sensitivity of obstacle is too high.
1.If not connect photocell, please make
sure that the 5 and 6, 5 and 7 short
circuit; if connect infrared sensor, please
make sure the wiring is correct and the
photocell is N.C.
2.Make sure that the photocell mounting
position can be mutually aligned.
3.Remove the obstacle.
4.Reduce the sensitivity of obstacle.
Remote control doesn’t work.
1.Battery level of the remote control
is low.
2.Remote control learning is not
completed.
1.Change the remote control battery.
2.Re-conduct remote control learning.
Press OPEN, CLOSE button,
the gate is not moving, motor
has noise.
Gate moving is not smoothly.
According to the actual situation to adjust
the motor or the gate.
Leakage switch tripped.
Power supply line short circuit or
motor line short circuit.
Check wiring.
Remote control working
distance is too short.
Signal is blocked.
Connect external receiver antenna, 1.5
meters above ground.
The gate moves to the middle
position to stop or reverse.
1.Motor output force is not enough.
2.Sensitivity of obstacle is too high.
3.Gate meets obstacle.
1.Check whether the transformer power is
normal, if not, change the transformer.
2.Adjust the TR2.
3.Remove the obstacle.