EasyManua.ls Logo

JPI JP-33 - DEV Heater Overheats; Dry Heater Does Not Work

JPI JP-33
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JP-33 SERVICE MANUAL
Technical Support - Trouble Shooting
2.9- Dry Heater does not work.
Is there any change in voltage?
REFER TO TROUBLE SHOOTING SECTION 2.3
Dry Heater is defective.
If the heater is malfunctioning due to dry heater temperature fuse or thermostat, contact
technical support to replace heater.
2.10- DEV Heater overheats.
Check if there is sufficient DEV and FIX chemicals in the Tank.
Check the developer and fixer tanks levels and also check replenishment tank levels.
Check if there is air in DEV and FIX pipes.
If there is air bubbles in a pipe, hose or pump the heater can overheat because of poor
circulation.
Turn off power supply and open the Drain Valve to drain air.
- -
24