6-6 
Symptom of Error  Possible Cause or Cause of Fault  Countermeasures 
The control unit malfunctions.  Replace  the  CDJ-2779  circuit 
board. 
The illumination does 
not light. 
 
The LCD malfunctions.  Replace the LCD. 
The transponder power supply is 
not turned on. 
Turn on the transponder power 
unit. 
The whip antenna is damaged.  Replace the whip antenna. 
No AIS message is 
received. 
 
 
 
 
 
The following alarm number 
appears: 003, 004, or 005. 
The synthesizer in the receiving 
circuit is unlocked. 
Replace the transponder. 
The following alarm number 
appears. 
001, 052, 53: Power circuit fault 
001, 054: PA collector current 
abnormal 
001, 055: PA temperature 
abnormal 
001, 058: PA protection circuit 
operated 
001, 060: TX synthesizer unlock 
operated 
003, 004, 005: RX synthesizer 
unlock operated 
Replace the transponder. 
001, 057: Antenna not connected  Check that the antenna is 
connected. 
Check setting of the external and 
internal antennas. 
No AIS message is 
transmitted. 
001, 002: VSWR abnormal  Check that the antenna is 
connected. 
Check that there are no objects 
around the antenna. 
Replace the antenna and check for 
normal transmission. 
The polarity of the serial cable is 
incorrect. 
Check if the polarity is correct and 
connect it. 
The interface between the sensor 
and connection box is incorrect. 
Check if the interface is correct 
before its connection. 
The sentence that the sensor 
generates is not supported by the 
AIS. 
Check the output command and 
the version. 
The serial format (baud rate, etc.) 
does not meet the setting of the 
controller. 
Check the serial format of the 
sensor. 
The sentence that the sensor 
generates does not match the 
sentence setting of the controller. 
Check the serial format of the 
sensor. 
The valid/invalid sensor data flag 
is invalid. 
Check if the sensor is working 
correctly. 
The sensor (GPS, gyro, 
rate-of-turn indicator) 
malfunctions. 
Replace the sensor. 
Sensor data (external 
GPS, gyro, and 
rate-of-turn) cannot 
be loaded. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The control unit malfunctions.  Replace  the  CDJ-3182  circuit 
board.