5-48
5.3.4.4 LONG RANGE RESPONSE SETTINGS
To set the Long Range Response, select 4.LONG RANGE RESPONSE .
Auto response (AUTO) and manual response (MANUAL) can be selected.
This setting works when a long range communication device is connected.
The default setting is AUTO. Use the Jog Dial for selection and confirmation.

Long Range Response Screen
5.3.4.5 BUZZER SETTINGS
To set the buzzer beeping functions, select 5.BUZZER .
Each buzzer functions can be set enable (ON) or disable (OFF) as followings..
BUZZER : ON / OFF
ON : Key touch beeping is enable and the other buzzer function can be work by the each setting.
OFF : All buzzer functions are disable including key touch beeping.
MESSAGE : ON / OFF
When a binary message is received.
GUARD ZONE ALARM : ON / OFF
When a other ship approaches within the guard zone range
LOST TERGET ALARM : ON / OFF
When a other ship information within the range is not received for 6 minutes.
ALARM : ON / OFF
When a failure alarm occurs.
Setting of Buzzer functions
3. LONGRANGERESPONSE
:AUTO
5.BUZZER:ON
-MESSAGE:ON
-GUARDZONEALM:OFF
-LOSTTARGETALM:OFF
-ALARM:ON