8-3
8.4.3 Supported interface sentences
Indication Sentence format Supported sentence formatters
Input data Recommend Optional
Longitude/Latitude
Position Accuracy
Time of Position
GNS
GLL
GGA
RMC
Datum Reference DTM
RAIM Indicator GBS
Speed Over Ground
(SOG)
VBW VTG
OSD
RMC
Course Over Ground
(COG)
RMC VTG
OSD
Heading HDT OSD
Rate of Turn (*1) ROT
1.
SENSOR1-1
SENSOR2-1
SENSOR3-1
SENSOR1-2
SENSOR2-2
SENSOR3-2
SENSOR4-1
IEC61162-1/2
ITU-R M.823-2
Input: RTCM SC-104 Ver.2.0 Type 1, 2, 7, 9
2.
NSK
IEC61162-1 Input: VHW
3.
AUX1
AUX3
IEC61162-2
IEC61993-2
Input: ABM, ACA, ACK, AIR, BBM, LRI, LRF, VSD,
SSD(AUX1,AUX3)
Output: ABK, ACA, ALR, DSC, DSI, LRF, LR1, LR2,
LR3, TXT, VDO, VDM
4.
AUX2
AUX4
IEC61162-2
IEC61993-2
Output: ABK, ACA, ALR, DSC, DSI, LRF, LR1, LR2,
LR3, TXT, VDO, VDM
5.
LONGRANGE
IEC61993-2 Input: LRI, LRF
Output: LRF, LR1, LR2, LR3
6.
MAINTE
Prepared for future use
(*1) Rate of Turn includes errors caused by calculation in the range of +/- 5.6 degree/minute.
8.5 POWER SUPPLY UNIT (NBD-577B)
(1) Input voltage : 100-120 / 200-220 Vdc ±10%, 50/60Hz Single phase
: 24Vdc (Back up power supply)
(2) Output voltage : Typ. 24Vdc (19-35Vdc)