6-26
OPTO inputs:
I10 OPTO IN 1
ALARM MUTE
to
I13 OPTO IN 4
LOG 2 MAIN
The Sig. Distributor is equipped with four opto-isolated inputs that can be used to control the
system. Each input can be set according to the following list:
OPTO inputs Function
ALARM MUTE Mute an ESD Alarm
ES 2 MAIN ES 2 (LOG 2) becomes the active Echo Sounder
LOG 2 MAIN LOG 2 becomes the active lo
LOG 1 BT MUTE Mutes the BT / SOG transmitter of LOG 1
LOG 2 BT MUTE Mutes the BT / SOG transmitter of LOG 2
SD4 INVERT OFF Deactivates the inverting function for an SD4 INVERTED
output channel. When active, the SD4 INVERTED nmea
output channels are identical to an SD4 nmea output.
Table 1 OPTO input list
5.2.4 Menu M, Miscellaneous
When pressing the MENU button in the I0 INPUTS menu, M0 MISC is displayed.
M0 MISC
WRITE ACCESS OFF
Example of settings:
- Restore to default menu settings
- CPU Reboot
- Display SoftWare REVISION
- Display FirmWare REVISION
- Display HardWare REVISION
- ACCESS LEVEL
See table “Menu function summary” For a complete MENU list.
5.2.5 Menu N, NMEA out
When pressing the MENU button in the M0 MISC menu, N0 NMEA OUT is displayed.
NO NMEA OUT
WRITE ACCESS OFF
Setting concerning NMEA outputs are set under this menu.
For example:
- NMEA listeners
- Transmit baud rate
NMEA listeners:
N1 NMEA OUT1
ESD
to