6-27
N8 NMEA O 16-23
SPEED+DEPTH
Which type of NMEA listeners that are connected to the Sig. Distributor can be set in menu N1
to N8. These settings control which NMEA messages are transmitted on each output. Each
NMEA output is filtered according to the filter-file in use, see 6 NMEA filtering.
5.2.6 Menu O, Outputs
When pressing the MENU button in the N0 NMEA OUT menu, O0 OUTPUTS is displayed.
O0 OUTPUTS
WRITE ACCESS OFF
Setting concerning analogue, relay and opto outputs are set under this menu.
Analogue outputs:
O1 ANALOG OUT 1
WTL
Longitudinal water speed
O1.01 ANA OUT 1
0.1 V/KNOTS
Scale factor for output 1
O2 ANALOG OUT 2
BTR
Resulting ground speed
O2.01 ANA OUT 2
0.1 V/KNOTS
Scale factor for output 2
Relay and OPTO outputs:
O3 RELAY K1
FAIL LOG 1 REDUN
to
O18 OPTO 8
PULSE F BTR 200P
Program a threshold value for relay and / or OPTO outputs:
Example to set OPTO out 1 to a threshold value of WTL higher than 8kn:
Use the MENU button to go to menu O11
O11 OPTO 1
PULSE A WTL 200P
Use the + button to go to the function WTL HIGH THAN 0
O11 OPTO 1
WTL HIGH THAN 0
Press the ENTER button
O11 OPTO 1
SAVING...
Press the ENTER button once more to reach sub menu O11.1