6-28
O11.1 OPTO 1
WTL HIGH THAN 0
Use the + button to set the value 8kn
O11.1 OPTO 1
WTL HIGH THAN 8
Press the ENTER button to save the value 8kn
Each relay and opto output can be programmed to indicate a specific function (see table below).
Relay + opto out Function
FAIL LOG 1 MAIN No NMEA from LOG 1 main
(
power fail
)
FAIL LOG 2 MAIN No NMEA from LOG 2
(
power fail
)
FAIL LOG 1 REDUN No NMEA from LOG 1 redundanc
y
(
power fail
)
ESD ALARM Alarm from Echo Sounder Displa
y
PULSE A WTL 200P Pulse timer A
(
Default set to WTL 200P/NM
)
Menu S9
PULSE B WTT 200P Pulse timer B
(
Default set to WTT 200P/NM
)
Menu S10
PULSE C WTR 200P Pulse timer C
(
Default set to WTR 200P/NM
)
Menu S11
PULSE D BTL 200P Pulse timer D
(
Default set to BTL 200P/NM
)
Menu S12
PULSE E BTT 200P Pulse timer E
(
Default set to BTT 200P/NM
)
Menu S13
PULSE F BTR 200P Pulse timer F
(
Default set to BTR 200P/NM
)
Menu S14
WTL ASTERN WTL Forward or Astern, Energized relay (Closed contact) =
Astern
WTT PORT WTT Port or Starboard, Energized relay (Closed contact) =
Port
WT INVALID De-ener
g
ized rela
y
(
Open contact
)
= Invalid STW / WT
BTL ASTERN SOG longitudinal (BTL) Forward or Astern, Energized relay
(
Closed contact
)
= Astern
BTT PORT SOG transverse (BTT) Port or Starboard, Energized relay
(
Closed contact
)
= Port
BT INVALID De-ener
g
ized rela
y
(
Open contact
)
= Invalid SOG
BT DEPTH INVALID De-ener
g
ized rela
y
(
Open contact
)
= Invalid BT DEPTH
WTL HIGH.THAN XX XX is the lon
g
itudinal STW threshold value in knots
WTT HIGH.THAN XX XX is the transversal STW threshold value in knots
WTR HIGH.THAN XX XX is the resultin
g
STW threshold value in knots
BTL HIGH.THAN XX XX is the lon
g
itudinal SOG threshold value in knots
BTT HIGH.THAN XX XX is the transversal SOG threshold value in knots
BTR HIGH.THAN XX XX is the resultin
g
SOG threshold value in knots
WTL LOW.THAN XX XX is the lon
g
itudinal STW threshold value in knots
WTT LOW.THAN XX XX is the transversal STW threshold value in knots
WTR LOW.THAN XX XX is the resultin
g
STW threshold value in knots
BTL LOW.THAN XX XX is the lon
g
itudinal SOG threshold value in knots
BTT LOW.THAN XX XX is the transversal SOG threshold value in knots
BTR LOW.THAN XX XX is the resultin
g
SOG threshold value in knots
Table 2 Relay and OPTO out