9-15
S6 Lock Timeout
Time=NNN seconds
4.2.12.6 Menu S7 NMEA interval
The requested NMEA sentence transmission interval is set with this menu.
Press "+" or "-" to change the value. Time resolution is 0.01 seconds.
Save selected value by pressing ENTER.
S7 NMEA interval
Time= R.RR sec
4.2.12.7 Menu S8 PSALN telegram
The transmission of the proprietary PSALN telegram used for
measurement quality is enabled with this menu. Press "+" or "-" to change
value. Save selected value by pressing ENTER.
S8 PSALN Telegrm
DISABLED
4.2.12.8 Menu S9 VBW format
The IEC 61162-1 /NMEA 0183 VBW sentence version is set with this
menu. Press "+" or "-" to change the format to extended (with stern
speeds) or short (first edition). Save selected value by pressing ENTER.
S9 VBW Format
Extended
4.2.12.9 Menu Sa Operating frequency
The transmission frequency is set with this menu. Press "+" or "-" to
change the value in steps of 500 Hz. Default frequency value 150 kHz
should always be used unless contact with manufacturer recommends
another value. Available frequency values are between 145000 - 155000
Hz. Save selected value by pressing ENTER.
SA OperatingFreq
150000 Hz
4.2.13 Menu T0 TEST menus
End user and service personnel are intended to use these menus for test.
WARNING: the log stops to operate when any test menu is selected.
Press "+"to change to “WRITE ACCESS ON” and then ENTER to go
into settings sub menus.
T0 TEST
WRITE ACCESS OFF