[3]  Depth Graph Setting > 
 
•  The Depth Graph Setting menu will appear. 
 
 
[1]  Depth Graph Display 
 
•  Determine whether to display received water depth information with a graph. 
•  One of two digital information areas is used to display data. 
•  When the water-depth graph is displayed, the sizes of the target tracking (TT) / AIS information 
areas are exclusively decreased. 
•  Put the cursor on the digital information display    Target    (menu  ①  on page 2-27), and press the 
[ENT] key.    The water-depth graph display function is switched between on and off. 
  Off      : Does not display a water depth graph. 
  Area1    : Displays the water depth graph in digital information area 1. 
  Area2    : Displays the water depth graph in digital information area 2. 
 
 
[2] Depth Range 
 
•  Select the depth range on the water depth graph. 
  50m     : Sets 50 m as the depth range. 
  100m   : Sets 100 m as the depth range. 
  250m    : Sets 250 m as the depth range. 
  AUTO    : Uses the depth range in the DPT sentence included in received data. 
 
 
[3] Time Range 
 
•  Select the time range on the water depth graph. 
  10min    : Sets 10 minutes as the time range. 
  15min    : Sets 15 minutes as the time range. 
  30min    : Sets 30 minutes as the time range. 
  60min    : Sets 60 minutes as the time range. 
  12hour    : Sets 12 hours as the time range. 
 
 
[4] Depth Unit 
 
•  Set the unit of water depth for the water-depth graph. 
  Feet     : The feet is used as the unit of water depth. 
  Fathom    : The fathom is used as the unit of water depth. 
  Meters    : The meter is used as the unit of water depth. 
 
 
3-93