[IV] Receive Sentence Setting (RX Sentence) 
 
Select Use/no Use for each sentences. 
The system is factory-set for using all sentences. 
To receive only specified sentences, select    No Use    for sentences which are not necessary. 
 
  Procedures    1.  Open the Serviceman Menu. 
 
2.  Open the RX Sentence menu by performing the following menu 
operation. 
 
        2. Installation Menu   
 → 9. Next   
 → 5. LAN Port Setting   
 → 3. RX Sentence   
 
3.  Select the sentences used by the sensors to be set. 
 
Selection value:  Use  or  Not Use   can be selected for each sentence. 
 
 1. GPS(LL/COG/SOG)   : GGA/RMC/RMA/GNS/GLL/VTG 
 2. GPS(WPT/Time)   : GGA/RMC/RMB/BWC/BWR/ZDA 
 3. Depth     : DPT/DBK/DBT/DBS 
 4. Wind     : MWV/MWD 
 5. Current     : 
  Data Set Number    : 0-9. Set the number of the sentence to be used by 
Data Set Number.  (Initial value All) 
  Layer A    : 0-999. Set the number of the sentence to be used 
with layer A by Layer Number.    (default value : 3) 
  Layer B    : 0-999. Set the number of the sentence to be used 
with layer B by Layer Number.    (default value : 4) 
  Layer C    : 0-999. Set the number of the sentence to be used 
with layer C by Layer Number.    (default value : 5) 
    6. Autopilot      : APB (default value : Not Use) 
 
7-29