Magnetron Replacement Procedure for Scanner Unit NKE-1130 
(JMA-5332-12) 
 
 
(1)  Before starting part replacement work, turn off the 
safety switch of the scanner unit. 
The safety switch is located on the rear (stern) side.   
Remove the cover and turn off (to the lower side) the 
safety switch. 
Bow side 
Turn off the safety 
switch. 
 
 
 
 
 
 
 
 
 
 
 
 
(2)  Loosen the hexagonal bolts and remove the cover on 
the left (port) side 
Remove the eight 
hexagonal screws. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(3)  Check that there is no remaining electric charge 
in the modulation high-voltage circuit board. 
Remove the two screws (M4) holding the 
magnetron cables (both yellow and green). 
Magnetron 
Remove the 
yellow cable. 
Remove the 
green cable. 
Remove the 
two screws. 
8-15