JMA-9100/7100 Installation Manual > 4.INITIAL SETTING > 4.12 INITIALIZATION OF SCANNER OPERATION TIME
4-21
4
[II] Motor rotation time (Clear Motor Time)
Motor rotation time of the scanner is initialized.
When an scanner motor is replaced, initialize motor rotation time according to the
following procedures.
Procedures
1) Open the [Service Man Menu] screen.
2) Open the [2.Clear Motor Time] screen according to the operation shown below.
3) Select YES on the confirmation screen.
Motor rotation time stored in the control circuit located in the scanner is initialized
to 0.
[III] Storage of Scanner time (TXRX To Display Unit)
Scanner time that has been stored in the scanner is stored in the display unit.
When a control circuit in the scanner is replaced, store scanner unit time
according to the following procedures.
1. Storage of scanner time
2. Replacement of control circuit in the scanner unit
3. Recovery of scanner time
Procedures
1) Open the [Service Man Menu] screen.
3. Maintenance Menu
→
5. TXRX Time
→
2. Clear Motor Time