– 7 –
(3) Operation of the connection panel
1) Connecting procedure of CP-18/180 or IP-110F
Exclusive connectors are prepared for connection of the
connector for CP-18/180, IP-110F.
Paying attention to the orientation of the connector, con-
nect it to connector CN38 located on the circuit board.
After connecting, securely lock the connector.
1. After inserting the connector, put all cords together
with cable clip band
)
4
located on the side of the
box.
(Caution) 1. Fix the cord clamp and the cable clip
band ) following the attaching
procedure.
2.
When removing the connector, re-
move it from the wire saddle and
remove it while pressing the hook of
the cable clip band ).
How to fix cable clip band
))
How to remove cable clip band
Pushing the hook portion, push the band to remove it.
Pull
Push
Push the hook.
4
/
Panel
Panel
)
[Connection of the connector for CP, IP panel]