– 12 –
(5) Example of application
1) When the CP-180 is used together with the material end sensor (ED : optional), it can be used as a small
edge-controller.
(Method) Adjust the position to mark
of the CP-180, turn ON material end sensor ON/OFF switch of the
CP-160, and turn ON mark
of the automatic one-shot stitching.
(Caution) Number of rotations of the automatic one-shot stitching can be changed by the function set-
ting (No. 38).
)