EasyManua.ls Logo

Juniper ACX2100 - Page 77

Juniper ACX2100
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Clearance requirements
Cabinet airflow requirements
Table 26 on page 77 provides the cabinet requirements and specifications for the router.
Table 26: Cabinet Requirements and Specifications for the ACX2000 and ACX2100 Router
GuidelinesCabinet Requirement
You can mount the router in a cabinet that contains a
19-in. (48.3 cm) rack as defined in Cabinets, Racks,
Panels, and Associated Equipment (document number
EIA-310–D) published by the Electronics Industry
Association (http://www.eia.org).
NOTE: The cabinet must meet the strength
requirements to support the weight of the router.
The minimum cabinet size must be able to
accommodate the maximum external dimensions of
the router.
Cabinet size
The outer edges of the mounting brackets extend the
width of the chassis to 19 in. (48.3 cm).
The minimum total clearance inside the cabinet is 30 in.
(76.2 cm) between the inside of the front door and the
inside of the rear door.
Cabinet clearance