Table 5: SRX220 Services Gateway Specifications
ValueSpecification
1.73 in. x 14.31 in. x 7.11 in.
44 mm x 363 mm x 180.5 mm
Dimensions (H x W x D)
•
3.43 lb (1.56 kg) for SRX220H models without PoE
•
3.50 lb (1.59 kg) for SRX220H-POE models with
PoE
Chassis weight
No performance degradation up to 10,000 ft
(3048 m)
Altitude
Normal operation ensured in temperature range of
32°F (0°C) to 104°F (40°C)
Nonoperating storage temperature in shipping
container: -40°F (-40°C) to 158°F (70°C)
Temperature
•
SRX220 Services Gateway without PoE and
without Mini-PIMs: 126 BTU/hour (37 W)
•
SRX220 Services Gateway with two Mini-PIMs and
without PoE: 205 BTU/hour (60 W)
•
SRX220 Services Gateway with PoE and without
Mini-PIMs: 327 BTU/hour (96 W)
•
SRX220 Services Gateway with PoE and two
Mini-PIMs: 692 BTU/hour (203 W)
Maximum thermal output
NOTE: These specifications are
estimates and subject to change.
52 dB(A) or less per EN ISO 7779.Noise level
CAUTION: Before removingor installingcomponents of a functioning services
gateway, attach an electrostatic discharge (ESD) strap to an ESD point and
place the other end of the strap around your bare wrist. Failure to use an ESD
strap could result in damage to the services gateway.
Related
Documentation
SRX220 Services Gateway Description on page 3•
• SRX220 Services Gateway Front Panel and Back Panel Views on page 9
• Monitoring the SRX220 Services Gateway Components Using LEDs on page 128
• SRX220 Services Gateway Electrical Safety Guidelines and Warnings on page 65
Copyright © 2012, Juniper Networks, Inc.8
SRX220 Services Gateway Hardware