JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors 19
2.2 I/O descriptions
2.2.3 General power supply description
The Ethernet modules can be used in the allmost all the MAC motors but please be
aware that to use the MAC50 to 141 they will need the special option : “A009” for ex
-
ample “MAC140-A1-AAAA-A009”
. The diagram below shows how to connect power to a MAC400 motor mounted with
a MAC00-Ex4/-Ex41 module. Please notice that the voltage connected to P+ and/or CVI
must stay in the range +12-26VDC. When using a MAC50 to 141 up to 48VDC is al
-
lowed.
See also the general power supply description in the MAC motor main manual LB0047.
For further information concerning physical connections, see the Expansion module
MAC00-Ex4 (basic version) connector description, page 22.
with MAC00-Ex4
MAC400 Motor
with MAC00-Ex4
P+
P+
P-
P-
CVI
CVI
Power
Supply
Power
Supply
Control Volt.
Control Volt.
Mains 115 or 230VAC
Mains 115 or 230VAC
Main supply
Main supply
line is used for each motor.
Power supply
Make sure that all
involved units are
connected to the same
potential
GND
+12-26VDC
(control voltage)
Power supply connections to a MAC400
mounted with a MAC00-Ex4 module.