EasyManua.ls Logo

Kaba E-Plex 5000 - Battery Life and Replacement; Battery Management

Kaba E-Plex 5000
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
Procedure 11 - Activate All User Access Codes
You may need to activate all users if you have de-activated the whole
group - after a lockout, for example. This procedure will re-activate all
regular and Service User Access Codes that are not active.
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command 398#.
3. Example of Complete Entry: 398#.
4. Enter another # to indicate the end of programming.
5. You have now activated all regular User and Service User
Access Codes.
Procedure 12 - Activate / De-activate Passage Mode
You have already programmed a default duration for a door to remain in
Passage Mode. When you enable Passage Mode, it becomes enabled
for the duration you have set in Procedure 5 - Program the Duration of
the Passage Mode period, on page 10.
If your length is 6 hours, and you enable Passage Mode at 1:00, it will
automatically re-lock at 7:00. Even if the lock was taken in and out of
Passage Mode multiple times during the six hour period, it will still re-lock
after six hours (programmable) from the original starting period. This
ensures that a lock will never remain in Passage Mode beyond the
programmed time period.
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command 399# to activate / de-activate Passage Mode.
3. Enter the code where 1 = activate Passage
Mode and 0 = de-activate Passage Mode.
4. Example of Complete Entry to activate Passage Mode 399#1#.
5. Enter another # to indicate the end of programming.
6. You have now activated Passage Mode on the door.