7
Reset Procedures
There are three different “Reset” levels available in the E-Plex 5000.
Code 099# will reset the lock to the factory default settings except
for the access code length (Master, Manager Access User codes
and Time / Date are retained if already programmed)
Code 299# will delete all access and service user codes (Master,
Manager and M-Unit * users are retained)
Hard Reset will return the lock to factory mode including deleting all
codes, putting the lock back to factory default values (4 digit access
code length) and making the master code 1-2-3-4-5-6-7-8. A hard
reset is performed as follows.
Insert key, turn and hold in open position.
Within 5 seconds, press # and then release latch
While red / green light flashes, press 1-2-3-4-5-6-7-8-# on keypad
The lock will reset. A green light with corresponding high pitch tone
indicates reset is complete.
Lock is now reset to the factory mode and the Master Code is now
1-2-3-4-5-6-7-8.
*M-Unit is only applicable when using optional E-Plex software.
Procedure 1 - Program the Access Code Length
Setting the length of Access Codes must be the first lock programmable
function you perform, because all your other access codes must have
the same length. If a user enters a code of a different length, the lock
will not accept it. Longer length Access Codes permit a greater number
of code possibilities, and thus higher security. The master code must
always be 8 digits
Required User Level: Master
1. To configure the E-Plex 5000 programmable pushbutton lock,
it must first be placed in Programming Mode.
Important: This is the only programmable function that
can be done during the factory mode using the factory
master code. Except for changing from the factory code to a
new master code.