24
Procedure 17 - Activate/De-activate Lockout Mode
You may need to use Lockout Mode, for example, during a fire or fire
drill when you do not want anyone to return to his or her office. This
procedure will de-activate all regular User Access Codes that are active,
including Manager Codes, but excluding the Master Code.
Required User Level: Master
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command 499# for Lockout Users Mode (except Master).
3. Enter 1# to activate Lockout Mode and 0# to disable it.
4. Example of Complete Entry: 499#1# or 499#0#.
5. Enter another # to indicate the end of programming.
6. You have now activated or de-activated Lockout Mode.
Procedure 18 - Perform Manual Diagnostics
Use the Diagnostic Code to perform manual diagnostics of the lock,
green LED, red LED, buzzer, and the twelve pushbuttons - 0 through 9,
* and #.
Required User Level: Master
1. Put the lock into Pushbutton Programming Mode.
2. Enter Command 500# for Diagnostics.
3. You will see a green LED and hear a high beep followed by a
red LED and a low beep.
4. Enter 1234567890*#, in that order exactly, to test each push-
button. If every pushbutton is working correctly, you will see
a
green LED and hear a normal beep for each pushbutton that
is pressed.
5. Example of Complete Entry: 500#1234567890*#.
6. Enter another # to indicate the end of programming.
7. If you see a red LED at any time you are pressing a push-
button, or at the end of the code, there could be a problem with
the pushbuttons.