28
Summary of Pushbutton Programming Commands
Name
Activate
Users
De-activate
Users
Diagnostic
Communication
Startup
Command
300 #
NNN#
301 #
NNN#
302 #
NNN#
303 #
398 #
399 #
P#
400 #
NNN#
401 #
NNN#
402 #
NNN#
403 #
498 #
499 #
L#
500 #
1234567890*#
900 #
Description of Command
‘Activate User Access Code’
NNN = specific User ID location (001 to 099)
‘Activate Manager
Access Code’
NNN = specific User ID location (001 to 099)
‘Activate Service User
Access Code’
NNN = specific User ID location (001 to 099)
‘Activate M-Unit User Code’
‘Activate all User Codes’ (except Master,
Manager and M-Unit User)
‘Activate / De-Activate Passage Mode’
(P = 0 or 1; 0 = disable Passage Mode;
1 = enable Passage Mode)
‘De-Activate User Access Code’
NNN = specific User ID location (001 to 099)
‘De-Activate Manager Access Code’
NNN = specific User ID location (001 to 099)
‘De-Activate Service User Access Code’
NNN = specific User ID location (001 to 099)
‘De-Activate M-Unit User Code’
‘De-Activate all User Codes’ (except
Master, Manager, and M-Unit User)
‘Activate / De-Activate Lockout Mode’
(Master User doesn’t affect by Lockout
Mode) (L = 0 or 1; 0 = disable Lockout
Mode; 1 = enable Lockout Mode)
‘Manual diagnostic’
‘Communications startup’
Authorization
Master, Mgr
Master
Master, Mgr
Master, Mgr
Master, Mgr
Master, Mgr
Master, Mgr
Master
Master, Mgr
Master, Mgr
Master, Mgr
Master
Master, Mgr
Master, Mgr