Page 21
INSTALLATION GUIDE - REMOTE ACCESS CONTROLLER RAC 4XT • PK3191_10_14
6.0 Annex A Wiring Diagram and Tables Continued
Table 2
Table 7
Remote
Programming
Interface
Peri
heral
Controller Board - RAC 4 Peripherals Connections
LED
D41
D42
D43
12
13
14
Access Delay (SW2 on Controller Board)
Descri
tion
Pro
rammin
2
3
4
5
6
11
GND
J8 pin 3
J8
in 4
J18
in 3
J18
in 4
Rela
Ex
. Bd.
Remote unlock
Request to Exit
-
Black
Black
Strike or
Maglock
SW1-1
NC
SW1-3
NO
GND
J6
in 3
J6
in 4
3-2
2-3
COM
SW1-2
Descri
tion
Initialization
PCB Status LEDs
D44
4-2
1-3
3-1
6-1
5-3
D45
D46
NO
NC
COM 6-2
6-3
-
(O)
(Q)
-
Item*
-
TB1
in 1
(P)
-
J17
in 2
J17
in 3
Low Batt
AC Fail
GND
Fire Alarm
J16
in 1
-
3
5
ON
FIRE ALM
10
J8 pin 1
J8
in 2
7
15
20
TB1
in 4
TB1
in 3
Controller Board
-
12V LCK
GND
(K) - Strike
(L) - Maglock
-
-
-
ON
8
2-1
TB1
in 2
Table 3
35
OFF
10 OFF
9
J16
in 2
J17 pin 1
12V
ID
GND
REX
H
NO
COM
-
40
50
J19
in 3
ON
-
16
AC Fail
RED
BLACK
BROWN
WHITE
-
RE-INIT
NC
DC Power
3-3
REM UNL
GND
4-1
NO
J19
in 1
J19 pin 2
J6
in 2
SW3-2
SW3-3
-
COM
Terminal
J6
in 1
PCB Conn.
J5
1-2
Table 4
ID
J9
Rela
0
Functionalit
1
J18 pin 1
J18 pin 2
4-3
90
12015 OFF
2-2
GND
TX
Rela
Ex
.
RX
CGND
Si
nal
DB9
ON
ON
ON
2
ON
OFF
CFG
1
Sec.
8
1ON
ON
4
ON
ON
25
OFF
OFF
OFF
OFF
OFF
OFF
60
30ON
ON
OFF
OFF
ON
ON
OFF
OFF
3
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
NO
NC
Functionalit
2
Pro
rammin
Access
NC
COM
OFF
Relay Expansion Board
ON
OFFON
OFF
OFF
OFF
8-1
7-1
7-2
7-3NO
SW3-1
ON
ONOFF
ON
ON
5-2
OFF
Wire / Conn.
1-1
ON
OFF
B
ass State
NC
B
ass
Table 6
Wire Color
ORANGE
RED*
Wire Color Connector
Controller Board
Description
+
-
ID
NC
-
NC
NO
XFMR-1
( - )
+
+
YELLOW
+
-
1
ON
OFF
ON
North America
-
-
BLACK / WHITE
ON
OFF
OFF
ON
OFF
ON
BLACK
Wire Color
International
Table 5
ON
OFF
1
2
1
2
XFMR-1
XFMR-2
8-3 NO
T
e
If bypass switches are "ON" - Relays are bypassed
& GREEN LEDs are "OFF".
If bypass switches are "OFF" - GREEN LEDs are
"ON" & Controller Board can activate relays.
SW1-4 SW3-4
Ada
tor
Table 8
COM
Si
nal
ID
XFMR-2
AC Fail-3
Si
nal
DC OUT-2
DC OUT-1
Low BAT-3
Controller Board to RAC 4XT Power Supply
-
DC OUT-2
-
NO
-
Si
nal
RED
RED*
-
+
*Denotes com
onent identifier in wirin
dia
ram of
revious
a
e.
LEDs
Power Supply to RAC 4XT LEDs
COM
Caution:
Power Supply to Power Adaptor
P. Su
l
Power Su
l
Power Su
l
8-2
Battery Status
Power Status
Description
Si
nal
AC Fail-1
-
LOW BAT-1
NC
NC
COM
State
NC
COM
NO NO
Terminal
5-1
(3)
Wire connection to back of contactless card reader.
J3 pin 3
J3 pin 4
Ingress
Swipe
J3 pin 1
J3 pin 2
Controller Board - RAC 4 Card Reader Connections
Controller Board
J1 pin 1
J2 pin 2
J2 pin 3
R71-6XXX
TB-2
TB-1
RED
(1)
Verify correct swipe reader model before connecting wires.
-
PURPLE
J2 pin 1
Wire Color
J1 pin 2
J1 pin 3
-
PURPLE / BLACK
WHITE TB-4
WHITE
-
TB-3WHITE / BLACK
YELLOW
YELLOW / BLACK
-
RED
--
GREEN
Red LED +
-
Green LED + -RED
-
-
RED / BLACK
Green LED -
Red LED - -YELLOW / BLACK
(2)
Contactless reader jumper wires must be installed as per wiring diagram:
J2 pin 1 to J3 pin 1 & J2 pin 2 to J3 pin 2 for Ingress
J12 pin 1 to J13 pin 1 & J12 pin 2 to J13 pin 2 for Egress.
-
-
-
RED / BLACK
YELLOW
Signal
Data +
Data -
Reader Config
Vcc (5V)
GND
12V
Term Block
BLACK
-
WHITE / BLACK
Insert
Contactless
PURPLE / BLACK
PURPLE
WHITE
R71-4XXX
Wire ColorWire Color
R79-1N1
-
-
TB-6
TB-7
RED
TB-4
WHITE
TB-3
-
GREEN
-
-
-
-
-
-
-
Term Block
BLACK
Wire Color
R79-1E1
-
-
(4)
TB-1 (BLACK)
TB-2 (RED)
TB-5 (YELLOW)
Factory Connected
-
-
-
-
-
-
J4-2
J4-1
J5-2
J5-1
Term Block
-
-
-
-
-
-
BLACK
RED
WHITE
GREEN
Wire Color
R79K-1XX-XX