EasyManua.ls Logo

Kaba RAC 4XT - Page 28

Kaba RAC 4XT
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 27
INSTALLATION GUIDE - REMOTE ACCESS CONTROLLER RAC 4XT • PK3191_10_14
6.0 Annex B Peripheral Wiring Diagrams
RAC 4XT PCB
5V
NO
5V GND 12V 1 2 3 1 2 3 4
NC COM GND FIRE GND COMNCNO12VGNDLBATACFGND
GNDDOORGNDTPRGNDREXGNDREM CGNDTXRXGND
12V
GND
J1
J15
J8 J7 J6
J14 J13 J12
J16 J17 J18
Fire Alarm Panel Connection
(See Notes 2 and 3)
Relay Override Switch
(See Note 5)
Ribbon Cable
(See Note 1)
Elevator
Control Panel
Connections
(See Note 4)
Floor 8 Input
ELEVATOR CONTROL
PANEL
Floor 7 Input
Floor 6 Input
Floor 5 Input
Floor 4 Input
Floor 3 Input
Floor 2 Input
Floor 1 Input
J19
J2 J3
12V 1 2 3
1 2 31
1 2 3
1 2 3 1 2 3 1 2 3 4
1 2 3 1 23 41 21 2 3
2 3
1 2 3 4
1 2 3 4
1 2 3 4 1 2 3 4 1 2 3 4
NO
4
1
1
ON
2 3 4
4
4 3
3 5
5
5
6
6
7
7
8
8
8
2
2
1
1
C NC
NO C NCNO C NCNO C NCNO C NC
NO C NC NO C NC NO C NC
1
ON
2 3 4
0
9
8
7
6
5
4
3
2
1
Note 1: Make sure all the wiring is complete, including the ribbon cable, before applying power to the RAC 4XT to ensure proper Relay
Expansion Board functionality.
Note 2: The relay outputs are “fail safe”. Accordingly, they are energized in their normal state and the relay status LED is ON. Upon power
failure, or when the Fire alarm input is activated (when connected to a Fire Alarm panel), the relay state will change and access will
be automatically granted. The relay status written (NC or NO) is correct when unit is powered.
Note 3: If the Fire Alarm Panel connection is not required, place a jumper wire between pin 3 and 4 of J18.
Note 4: In this example, the Normally Open relay outputs are used. Relay 2 controls access to Floor 7 and Relay 3 controls access to Floor
8. Actual wiring is specific to each application.
Note 5: For normal operation, set the relay override switches to the Off position (the relay status LED will be ON). Set the relay override
switch to ON to override the relay (the relay status LED will be OFF).
Note:
Expansion Board
drawing not to
scale
LOW BATT AC FAIL
NO C
DC BAT
INPUT
XFRM
OUT
+ - + -
NC NO C NC
Power Supply
Power Adaptor
Figure 13: Power Adaptor to Power Supply PCB Wiring
Figure 12: Relay Expansion Board Outputs Wiring