EasyManuals Logo

Kaba RAC 4XT User Manual

Kaba RAC 4XT
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
Page 33
INSTALLATION GUIDE - REMOTE ACCESS CONTROLLER RAC 4XT • PK3191_10_14
6.0 Annex D Quick Troubleshooting Guide
6. Programming and Auditing Troubleshooting
Symptom Action
Cannot program or audit the RAC
4XT
- Verify that the RAC 4XT controller is active: the
Functionality 1 (D45) and Functionality 2 (D46)
LEDs should blink. If not, reset the RAC 4XT
Controller: press the Reset switch (SW1) or
disconnect and reconnect the power.
- Verify that the cable between the RAC 4XT and
the FDU or IPM is connected properly.
- If the RAC 4XT is not initialized (Initialization LED,
D41, is OFF):
Follow the instructions in Section 5.2 "Hotel ID
Initialization".
- If the RAC 4XT was already initialized, it may need
to be re-initialized:
Follow the instructions in section 5.3 “Hotel ID
Re-Initialization”.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kaba RAC 4XT and is the answer not in the manual?

Kaba RAC 4XT Specifications

General IconGeneral
BrandKaba
ModelRAC 4XT
CategoryIP Access Controllers
LanguageEnglish

Related product manuals