Installation
6 --- 33
Connect the machine to the mains power supply in accordance with Fig. 12 and the
electrical diagram in chapter 13.1.4.
1
Fig. 12 Electrical Connection
1 User---provided main switch and fusing
6.5 Options
6.5.1 Machine fixing (option H1)
If the machine is supplied with mountings, these can be used to anchor it to the floor. De-
tails of the fixing holes are contained in the dimensional drawing in chapter 13.1.3.
Use appropriate bolts to anchor the machine.
6.5.2 Water cooling connection (option K2)
The dimensional drawing in chapter 13.1.3 gives the flow direction, size and position of the
cooling water connection ports.
Use connecting lines made of the appropriate material for the water system. Take into ac-
count the effect of electro---chemical reaction.
Keep the effect of pressure surge on the cooler as low as possible.
Where pressure surges are unavoidable provide an expansion tank to damp pulsations.