2
411d
Reading
Tel: +44 (0)118 9311188 | Email: info@able.co.uk
Aberdeen
Tel: +44 (0)1224 725999 | Email: ab@able.co.uk
Registered Address
ABLE Instruments & Controls Ltd
Cutbush Park, Danehill, Lower Earley,
Reading, Berkshire, RG6 4UT. UK.
Web
able.co.uk
E-commerce
247able.com
2 Kamstrup A/S 55121739_A3_GB_04.2016
MULTICAL® 403
Information
Permissible operating conditions / measuring ranges
Approved heat meter in accordance with MID and EN1434:
Temperature Range q: 2 °C…180 °C : 3 K…178 K
Flow sensor (temperature of medium) qq: 2 °C…130 °C
Approved cooling meter in accordance with DK-BEK 1178 and EN1434:
Temperature Range q: 2 °C…180 °C : 3 K…178 K
Flow sensor (temperature of medium) qq: 2 °C…130 °C
MID designation
Mechanical environment
Class M1 and M2
Electromagnetic environment
Class E1 (housing/light industry). The meter’s control cables must be drawn at min. 25 cm
distance from other installations.
Climatic environment
Non-condensing, closed location (installation indoors), ambient temperature 5…55 °C.
Maintenance and repair
The district heating supplier can replace temperature sensor pair, battery and communication
module. The flow sensor must not be separated from the calculator. Other repairs require
subsequent reverification in an accredited laboratory.
Selecting a temperature sensor pair
MULTICAL® 403-W - Pt500
MULTICAL® 403-T - Pt500
MULTICAL® 403-V - Pt100
Battery for replacement
Kamstrup type 403-0000-0000-200 (1 x D-cell)
Kamstrup type 403-0000-0000-100 (2 x AA-cell)
Communication Modules
For an overview of available modules we refer to section 9, page 18.

Other manuals for Kamstrup MULTICAL 403

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 403 and is the answer not in the manual?

Kamstrup MULTICAL 403 Specifications

General IconGeneral
TypeUltrasonic Heat Meter
Flow SensorUltrasonic
Pressure RatingPN16
Battery LifeUp to 16 years
ApprovalMID Class 2
DisplayLCD
CommunicationM-Bus, Wireless M-Bus, Modbus, BACnet
Power SupplyBattery
AccuracyClass 2
Protection ClassIP54
Housing MaterialComposite
Flow Rate Range0.6 m3/h to 15 m3/h