32
ABSORmatic
®
plus.
11.4 Error message:
Error 24 - (1200) Filter condition
I • Suction lines or filter blocked. LED
Functional disturbance "on".
C• Large foreign bodies may block suction
lines and/or filter. Error is indicated if
within 60 sec. (3x in series) after cle-
ning, LED "Filter full" is flashing.
R• Check suction lines, event. change filter.
11.5 Error message:
Error 25 - (1200) Low pressure fault
I • No reduced pressure is building-up,
although the suction motor is triggered.
C• a) Suction motor defect.
b) Suction hose is missin or not properly
connected.
c) Filter-lid is missing.
R• a) Replace suction motor.
b) Install suction hose or make proper
connection.
c) Install Filter-lid.
11.6 Error message:
Error 28 - (1200) EPROM defect
I • Component EPROM defect.
C• The EPROM is tested if the unit is swit-
ched on through power switch. This
error appears if the component is faulty
or indicates any malfunction at times.
R• Unit is out of order since prgrammable
memory is faulty. Consult customer ser-
vice dept. Request service.
11.7 Error message:
Warning 30 - (1201) Filter cleaning
I • Note, that soon filter cleaning starts.
C• Filter is nearly full.
R• Filter will be automatically vleaned at
the next stop.
11.8 Error message:
Warning 31 - (1201) Container level
I •Annunciator indicates full dust container.
C• Dust Container is full.
R• Empty dust container.
I = Instructions C = Cause R = Remedy