Preparatory measures
© KEB, 2015-07 COMBIVERT R6-N Page4.1 - 5
4
10
Observe
standards
The COMBIVERT R6 must not be started until it is determined that the installation complies
with 2006/42/EC (machine directive) (note EN60204).
The COMBIVERT R6 must not be started until it is determined that the installation complies
with 2006/42/EC (machine directive) (note EN60204).
The COMBIVERT R6 meets the requirements of the Low-Voltage Directive 2006/95/EC.
The harmonized standard of the series EN 61800-5-1 (VDE 0160) is used.
This is a product of limited availability in accordance with IEC 61800-3. This product may
cause radio interference in residential areas. In this case the operator may need to take
corresponding measures.
Transport, storage and installation
The storage of the COMBIVERT must be done in the original packing. It is to be protected against humidity
and excessive cooling and thermal effect. A long-distance transport must be carried out in the original packing.
Itistobesecuredagainstimpactinuence.Observethemarkingonthenalpacking!Afterremovingthenal
packing the COMBIVERT must be set down on a stable base.
Protect
Against Acci-
dental Con-
tact
The COMBIVERT R6 must be protected against invalid loading. Components and covers
must not be bent or moved as this may affect insulation distances. The units contain electro-
static sensitive devices which can be destroyed by inappropriate handling. For that reason
the contact of electronic devices and contacts is to be avoided. The equipment must not be
switched on if it is damaged as it may no longer comply with mandatory standards.
Make sure that during installation there is enough minimum clearance and enough cooling.
Climatic conditions must be observed in accordance with the instruction manual.
Hot
surface
Heat sinks can reach temperatures, which can cause burns when touching. If in case of
structural measures a direct contact cannot be avoided, a warning notice "hot surface" must
be mounted at the machine.
Electrical connection
Note Capac-
itor
all costs
Before any installation and connection work, the system must be switched off and secured.
After clearing the DC link capacitors are still charged with high voltage for a short period of
time. The unit can be worked on again, after it has been switched off for 5 minutes.
Secure
Isolation
The terminals of the control terminal strip are securely isolated in accordance with EN
61800-5-1. With existing or newly wired circuits the person installing the units or machines
must ensure that the EN requirements are met. With frequency inverters that are not iso-
lated from the supply circuit all control lines must be included in other protective measures
(e.g. double insulation or shielded, earthed and insulated).