COPYRIGHT KEMPPI OY
18 / Kempomat 2500, Kempomat 3200, Kempomat 4000 / 0340
Kempomat 2500, Kempomat 3200, Kempomat 4000 / 0340 / 19
COPYRIGHT KEMPPI OY
7.1. CABLES
Check the condition of welding and connection cables daily. Do not use faulty cables!
Make sure that the mains connection cables in use are safe and according to regulations!
The repair and mounting of mains connection cables should be carried out only by an authorized
electrician.
7.2. POWER SOURCE
NOTE! Disconnect the plug of the power source from the mains socket before removing the
cover plate.
Check at least every 6 months (twice a year):
- Electric connections of the unit - clean the oxidized parts and tighten the loosened ones.
NOTE! You must know correct tension torques before starting the repair of the joints.
- Clean the inner parts of the machine from dust and dirt e.g. with soft brush and vacuum
cleaner.
Do not use compressed air. Do not use pressure washing device!
- There is a risk that dirt is packed even more tightly into gaps of components!
Only authorized electrician shall carry out repairs to the machines.
8. REGULAR MAINTENANCE OF THE EQUIPMENT
Kemppi service repair shops make regular maintenance according to the agreement.
The major points in the maintenance procedure are listed as follows:
- Cleaning of the machine
- Checking and maintenance of the welding tools
- Checking of connectors, switches and potentiometers
- Checking of electric connections
- Metering units checking
- Checking of mains cable and plug
- Damaged parts or parts in bad connection are replaced by new ones
- Maintenance testing. Operation and performance values of the equipment are checked,
and adjusted when necessary by means of test equipment.
The amount of use and the working environment should be taken into consideration when plan-
ning the frequency of maintenance of the machine. Careful use and preventive maintenance will
help to ensure trouble-free operation.
9. ORDERING NUMBERS
Kempomat 2500 230 / 400 621425001
Kempomat 3200 230 / 400 V 621432001
Kempomat 4000 230 V 621440201
Kempomat 4000 400 V 621440401
KMW timer (Timer unit) 6219200
KMW sync (Synchronization unit) 6219100
MSD 1 (Volt / Ampere metering unit) 6185666
GH 20 (Gun holder) 6256020
Hub for wire reel 4289880
MT 25 3 m 6252023
MT 25 4,5 m 6252024
MT 32 3 m 6253023
MT 32 4,5 m 6253024
KMG 25 3 m 6252123
KMG 25 4,5 m 6252124
KMG 32 3 m 6253033
KMG 32 4,5 m 6253034
MMT 25 3 m 6252513MMT
MMT 25 4,5 m 6252514MMT