EasyManua.ls Logo

Kemppi Kempomat 2500 - POWER SOURCE

Kemppi Kempomat 2500
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COPYRIGHT KEMPPI OY
20 / Kempomat 2500, Kempomat 3200, Kempomat 4000 / 0340
Kempomat 2500, Kempomat 3200, Kempomat 4000 / 0340 / 21
COPYRIGHT KEMPPI OY
Rated voltage
Connection voltage
3~ 400 V
3~ 230 V
Connection capacity
230 V / 400 V
*) ED
60 % ED
100 % ED
Loading capacity
(nominal values)
*) ED
60 % ED
100 % ED
Control range
Voltage steps
Open circuit voltage max.
Efciency
Power factor
Fuse
Wire feeder unit
Diameter of feed roll
Wire feed speed
Filler wires
ø Fe, Ss
ø Cored wire
ø Al
Wire reel
max. weight
max. size
Gun connector
Temperature class
Operation temperature range
Storage temperature range
Degree of protection
External dimensions
length
width
height
Weight
230 V / 400 V
380 V -10 %...415 V +6 %
220 V -10 %...240 V +6 %
9.2 kVA *) 30 %
5.9 kVA
4.0 kVA
250 A / 26 V *) 30 %
180 A / 23 V
140 A / 21 V
40 - 250 A / 14 - 26 V
10 steps
35 V
250 A / 26 V 75 %
250 A / 26 V 0.95
8 A delayed
2-roll drive
32 mm
0...18 m / min
0,6...1,2 mm
0,8...1,2 mm
1,0...1,2 mm
20 kg
ø 300 mm
Euro
H (180 °C)
-20...+40 °C
-40...+60 °C
IP 23C
930 mm
440 mm
860 mm
80 kg
Kempomat 2500
The products meet conformity requirements for CE marking.
10. TECHNICAL DATA

Other manuals for Kemppi Kempomat 2500

Related product manuals