CS-1022, 1021, 1012
CS-1020, 1010
CHOP:
The display cannot be synchroniz-
ed with the input signal since the
chopping signal becomes the
trig-
ger source.
CH1:
Sweep is triggered by channel 1 signal
regardless of vertical MODE selection.
CH2:
Sweep is triggered by channel 2 signal
regardless of vertical MODE selection.
LINE:
Sweep is triggered by line voltage
(50/60 Hz).
EXT: Sweep is triggered by signal applied to EXT
TRIG INPUT jack © .
@ TRIG MODE
Three-position lever switch; selects triggering mode.
AUTO:
Triggered sweep operation when trigger
signal is present, automatically generates
sweep (free runs) in absence of trigger
signal.
NORM:
Normal triggered sweep operation. No
trace is presented when a proper trigger
signal is not applied.
X-Y: X-Y operation. Channel 1 input signal pro-
duces vertical deflection (Y axis). Channel
2 input signal produces horizontal deflec-
tion (X axis).
This operates regardless vertical MODE
selection.
@ TRIG MODE
Three-position lever switch; selects triggering mode.
AUTO:
Triggered sweep operation when trigger
signal is present, automatically generates
sweep (free runs) in absence of trigger signal.
NORM:
Normal triggered sweep operation. No trace is
presented when a proper trigger signal is not
applied.
X-Y: X-Y operation. Vertical input signal produces
vertical deflection (Y axis). EXT TRIG input
produces horizontal deflection (X axis).
@ VARIABLE Control
Fine sweep time adjustment. In the fully clockwise
(CAL) position, the sweep time is calibrated.
® VARIABLE Control
Fine sweep time adjustment. In the fully clockwise
(CAL) position, the sweep time is calibrated.
For X-Y operation, this control serves as the X axis
gain adjustment.
© SWEEP TIME/DIV
Horizontal coarse sweep time selector.
Selects calibrated sweep times of 0.2 /ts/div to 0.5 s/
div in 20 steps
(CS-1021,
CS-1012... 0.5 ^s/div to
0.5 s/div in 19 steps) when sweep time VARIABLE
control ® is set to CAL position (fully clockwise).
© SWEEP TIME/DIV
Horizontal coarse sweep time selector.
Selects calibrated sweep times of 0.2 /ts/div to
0.5 s/div in 20 steps (CS-1010... 0.5 /xs/div to
0.5 s/div in 19 steps) when sweep time VARIABLE
control ® is set to CAL position (fully clockwise).
(§) «<• POSITION, PULLx 10 MAG
Rotation adjusts horizontal position of trace. Push-pull
switch selectsx 10 magnification (PULLx 10 MAG)
when pulled out; normal when pushed in.
(§) POSITION. PULLx 10 MAG
Rotation adjusts horizontal position of trace. Push-pull
switch selectsx 10 magnification (PULLx 10 MAG)
when pulled out; normal when pushed in.
For X-Y operation, this control serves as the X axis
position control.
13