page 63 of 94© KEYMILE December 2015 EN/LZTBU 372 129/1 RC
94
Commissioning
9. Configure the blocked port line feed:
- Blocked Port Line Feed Enabled = true.
10. Configure the metering pulse:
- Metering Pulse Enabled = true.
11. The pulse on answer configuration is not applicable in the V5CAS opera-
tion mode.
12. The polarity reversal configuration is not applicable in the V5CAS opera-
tion mode.
13. Execute “Apply”.
Configure the advanced unit
parameters
Proceed as follows:
1. Navigate to the advanced unit parameters:
- AP:/unit-9, Configuration - Advanced Unit Parameters.
2. Set the CAS AIS debouncing time:
- CAS AIS Debouncing Time = 1.0 s.
3. Set the metering pulse after on-hook time-out:
- Time-Out = 4.0 s.
4. Select the pulsed no battery wires:
- Pulsed No Battery Wire Selection = a-b-Wires Disconnected.
5. Enable the loop current power management:
- Enable Loop Current Reduction = true.
6. Select the reduced loop current:
- Reduced Loop Current = 15 mA.
7. Execute “Apply”.
Configure the line test param-
eters
Proceed as follows:
1. Navigate to the line test parameters:
- AP:/unit-9, Configuration - Line Test Parameters.
2. Enable the cyclic line test:
- Enable Cyclic Line Test = true.
3. Select the line test schedule:
- Line Test Schedule = Daily.
4. Set the start date and time:
- Start Date And Time = 2010-01-01 02:00:00.
5. Enable the foreign voltage measurement:
- Foreign Voltage = true.
6. Enable the noise measurement:
- Noise = true.
7. Enable the capacitance measurement:
- Capacitance = true.
8. Set the line test time-out:
- Line Test Time-Out = 3.0 h.
9. Execute “Apply”.
Configure the line test alarm
thresholds
Proceed as follows:
1. Navigate to the line test alarm thresholds:
- AP:/unit-9, Configuration - Line Test Alarm Thresholds.