User Manual
SUPM1
page 64 of 94© KEYMILE December 2015 EN/LZTBU 372 129/1 RC
94
Commissioning
2. Select the resistance/isolation between a and b wire:
- a-b = 30 kOhm.
3. Select the resistance/isolation between a wire and GND:
- a-GND = 30 kOhm.
4. Select the resistance/isolation between b wire and GND:
- b-GND = 30 kOhm.
5. Select the foreign DC voltage between a and b wire:
-a-b = 20 V.
6. Select the foreign DC voltage between a wire and GND:
- a-GND = 20 V.
7. Select the foreign DC voltage between b wire and GND:
- b-GND = 20 V.
8. Select the foreign AC voltage between a and b wire:
- a-b = 5 Veff.
9. Select the foreign AC voltage between a wire and GND:
- a-GND = 30 Veff.
10. Select the foreign AC voltage between b wire and GND:
- b-GND = 30 Veff.
11. Select the noise level:
- Noise = 10 -dBm”.
12. Execute “Apply”.
Result: The unit parameters are configured.
Configure the port general
parameters
Proceed as follows:
1. Navigate to the general parameters:
- AP:/unit-9/port-1, Configuration - General.
2. Select the provisioning set:
- Provisioning Set = Set 1.
3. Select the loop current:
- Loop Current = 23.5 mA.
4. Set the input level:
- Input Level = 0.0 dBr.
5. Set the output level:
- Output Level = -7.0 dBr.
6. Select the priority:
- Priority = Normal.
7. Enable the cyclic line test for this port:
- Enable Cyclic Test = true.
8. Disable the DSL adaptation. The SUPM1 does not make use of this
parameter:
- Enable DSL Adaptation = false.
9. Execute “Apply”.
Configure the port CTP
parameters
Proceed as follows:
1. Navigate to the CTP parameters:
- AP:/unit-9/port-1, Configuration - CTP.