78 N5186A MXG and X-Series SA Measurement Guide
5G New Radio (NR) Measurements
5G Waveform, EVM, and ACP Analysis
Using the equivalent SCPI commands
On the MXG:
SYSTem:PRESet
RF1:FREQuency:CW 3.5GHZ
RF1:POWer:AMPLitude 0dBm
SIGNal1:MODE WAVeform
SIGNal1:WAVeform
/Examples/5GNR_1CC_FR1_30kHz_SCS_100MHz_256QAM_DCPunctured.
wfm
SIGNal1 ON
DM:OPTimization:CHANnel ACP
RF1:OUTPut ON
For multi-channel instruments, set RF Out (all) to On.
RFALl:OUTPut ON
On the X-Series Signal Analyzer:
SYSTem:PRESet
INSTrument:CONFigure: NR5G:ACP
CCARrier:REFerence 3.5GHZ
ACPower:CORRection:NOISe ON