l This command has been superceded by the SENSe:FUNCtion:CURRent and SENSe:FUNC-
tion:VOLTage commands, which should be used in new applications. SENSe:FUNCtion is still avail-
able for backward compatibility.
SENSe:FUNCtion:CURRent 0|OFF|1|ON, (@<chanlist>)
SENSe:FUNCtion:CURRent? (@<chanlist>)
SENSe:FUNCtion:VOLTage 0|OFF|1|ON, (@<chanlist>)
SENSe:FUNCtion:VOLTage? (@<chanlist>)
Enables or disables the current or voltage measurement function.
Parameter Typical Return
0|OFF|1|ON,
*RST current OFF; voltage ON
0or1
Enables current measurements: SENS:FUNC:CURR ON, (@1)
Enables voltage measurements: SENS:FUNC:VOLTON, (@1)
l These commands replace the previous SENSe:FUNCtion command and should be used in new
applications. SENSe:FUNCtion is still available for backward compatibility.
SENSe:FUNCtion:VOLTage:INPut MAIN|AUXiliary, (@<chanlist>)
SENSe:FUNCtion:VOLTage:INPut? (@<chanlist>)
Selects the voltage measurement input.
MAIN - selects the front panel binding posts as the measurement inputs.
AUXiliary - selects the rear panel auxiliary voltage inputs as the measurement inputs.
Parameter Typical Return
MAIN|AUXiliary, *RST MAIN MAIN or AUX
Selects the auxiliary voltage input: SENS:FUNC:VOLT:INP AUX, (@1)
SENSe:SWEep:OFFSet:POINts <value>, (@<chanlist>)
SENSe:SWEep:OFFSet:POINts? [MIN|MAX,] (@<chanlist>)
Defines the offset in a data sweep for triggered measurements. Positive values represent the delay
after the trigger occurs but before the samples are acquired. Negative values represent data samples
taken prior to the trigger.
Parameter Typical Return
–524,287 to 2,000,000,000|MIN|MAX, *RST 0 <offsetpoints>
Specifies -2048 offsetpoints: SENS:SWE:OFFS:POIN -2048, (@1)
Keysight N6700C Operating and Service Guide 283
5 SCPI Programming Reference