5.4 Sound level meter and averager integrator with storage function
The sound level meter processes the acoustic signal for each elementary integration time and stores results in a saved memory.
Measured and stored data for each integration time:
LXeq, DI : equivalent continuous sound level of acoustic pressure on the logging time and frequency weighted.
LUpk : level of maximum peak of sound pressure on the elementary integration time.
Measurement time expressed in DD/HH:MM:SS
Integration time :
Data storage is made according to logging time (DI) to choose from : 1s, 2s, 3s, 5s, 10s, 15s, 30s, 60s.
Note : In order to have permanent control of the sound pressure level before the launch of measurement, the sound level meter
calculates and displays the equivalent continuous level of acoustic pressure on a logging time of 0.5s.
5.4.1 Adjustment prior to measurement
1 – Select Leq-St mode : move the cursor with arrow keys to 1 and select 'Leq-St' with the scrolling knob key.
2 – Select the weighting frequency.
Possible choices are : A frequency weighting - C frequency weighting - Z frequency weighting.
Place the cursor with arrow key on the area 2 and select with scrolling knob A, C or Z.
3 – Select the weighting frequency of peak level of sound pressure : move the cursor with the arrows to 3
and select C or Z with the scrolling knob key.
4 – Select the DI logging time :
Place the cursor on 4 and select with the scrolling knob among :
1s, 2s, 3s, 5s, 10s, 15s, 30s, 60s.
5.4.2 Launch the measurement
In manual mode : directly press icon ,the timer starts and shows the measurement time
In I/O mode : see chapter « Launching a measurement in I/O mode ».
5.4.3 During measurement
During measurement, three screens inform the current measurement. They are accessible through the
scrolling knob key.
E1 : it is the main screen that displays the instantaneous measurements.
LXeq0,5 : equivalent continuous level of acoustic pressure over a systematic integration time of
0,5s.
LXeqDI : equivalent continuous level of acoustic pressure over the scheduled elementary
integration time
LXeq : equivalent continuous level of acoustic pressure on ongoing measurement time.
LUpk : level of maximum peak of sound pressure on the measurement time.
Measurement time expressed in DD/HH:MM:SS