➢ Press Esc key to quit this file and back to file selection main screen.
6.2.2 L-Leq mode file
When the file has been identified by its identification number:
➢ Press OK key to access to E1 main screen results.
• LUpk : level of maximum peak of sound pressure
• LXYmax : maximum value of sound pressure level weighted temporally met since the beginning of the measurement.
• LXYmin : minimum value of sound pressure level weighted temporally met since the beginning of the measurement.
• LXeq : equivalent continuous level of acoustic pressure frequency weighted on measurement time.
• LXE : level of exposure to sound frequency weighted
• D : measurement time expressed in DD / HH: MM: SS.
• % : percentage of saturation of the input stage.
➢ With scrolling knob key, go to E2 screen which reminds measurement configuration.
• Date of measurement start
• Date of measurement end
• Measurement time expressed in DD / HH: MM: SS.
• Measurement mode : L-Leq
• Frequency weighting for L and Leq : Weig.
• Time weighting for L : Cst
• Integration time for leq : S/S (Start/Stop mode)
• Frequency weighting of the level of peak pressure for L : LpK
➢ Press Esc key to quit this file and back to file selection main screen.
6.2.3 Leq-St mode file
When the file has been identified by its identification number:
Read the stored files 22
Stored file
E1 screen E2 screen Stored file
Stored file
E1 screen E2 screen Stored file