DIRECTION OF ROTATION IS COUNTER-CLOCKWISE SEEN FROM
FRONT ONTO THE COUPLING!
DRY-RUN OF MECHANICAL SEALS AND/OR SLIDE BEARINGS
MUST BE AVOIDED!
THE MECHANICAL SEAL MUST BE OPERATED WITH A SUITABLE
SEALANT LIQUID
THE QUENCH SYSTEM FOR THE MECHANICAL SEAL MUST BE
MONITORED BY THE INTENDED USER
THE INTENDED USER MUST ENSURE FLOW OF PRODUCT
THROUGH THE UNIT AT ALL TIMES
MEGATRON
DISPERSION WORKING CHAMBERS MAY NOT BE
OPERATED DRY – THE MECHANICAL SEAL IS COOLED AND
LUBRICATED BY THE MEDIUM BEING PROCESSED AND THE
QUENCH MEDIUM. RUNNING DRY WILL DESTROY THE
MECHANICAL SEAL