21. Remove ⅜” line and
replace plug in yellow port
22. Discard water in bucket
23. Close faucet
24. Open tank ball valve
25. Open faucet watch out
for spray
26. Wait for flow to drop off.
Close feed and allow
system to depressurize.
Leave faucet open.
27. Remove prefilter, postfilter and auxiliary
(if necessary) cartridge plugs
28. Install all remaining cartridges. (Cartridges
must already be prepared according to
their installation instructions). Use
cartridge plug for any unused auxiliary
port.
29. Slowly open feed
30. Wait for steady permeate
flow at the faucet then close,
remove anti-spray line.
Check for leaks
31. Inform customer to
discard first two tanks of
water.
plug
inserted