anti-spray line
Section 4: Sanitization Procedure for K5 WOW Install Household Bleach
(unscented) uses Sanitization Kit Part No. 9392A
Note: The following steps should be taken immediately after installation; no water should be in the unit.
Safety glasses and rubber/latex gloves must be worn during sanitization.
1. Attach anti-spray line
2. Close feed
3. Confirm jack screw is
closed
The faucet should be closed.
The feed valve should be closed
4. Install cartridge plugs in
all locations, except
prefilter
5. Add 5 mL unscented
bleach to a sanitization
cartridge (kit 9392A) that
is half full of clean water
6. Slowly open feed valve
7. Wait 4 minutes
Note: You may hear a
buzzing sound from
the unit. This is normal
for start-up. Check for
leaks.
8. Close feed
9. Slowly crack open faucet
to depressurize the
system
10. Allow system to
depressurize leave faucet
open.
WARNING: Do
not open faucet all
the way. Air, water
and chemical
solution will spray
out forcefully. Be
prepared to control
the anti-spray line.
Note: Do not over tighten.
Install 4 plugs in these locations.
(RO, Auxiliary 1, Auxiliary 2, Post)
prefilter position

Other manuals for Kinetico K5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kinetico K5 and is the answer not in the manual?

Kinetico K5 Specifications

General IconGeneral
Filter TypeReverse Osmosis
Daily Production Rate50 gallons per day
CertificationsNSF/ANSI 58
Filter Life6-12 months
Waste Water Ratio1:1

Related product manuals