K5 Drinking Water Station
Section 7 Drinking Water Systems Revised: 09/2016
Page 16
Install 4 plugs in these locations.
(RO, Auxiliary 1, Auxiliary 2, Post
Section 3: Sanitization Procedure for K5 Air Charge Install - Chlorine
Dioxide
Note: The following steps should be taken immediately after installation; no water should be in the unit.
Safety glasses and rubber/latex gloves must be worn during sanitization.
1. Attach anti-spray line
2. Close feed / open tank.
3. Confirm jack screw is
closed and the standard
tank spacer (gray) is
installed in the RO shutoff
position
The faucet should be closed.
4. Install cartridge plugs in all
locations, except prefilter
6. Slowly open feed valve.
Pour one package of cleaning agent
into dry cartridge plug – install plug into
cartridge prefilter position.
Cleaning Agent: Chlorine dioxide tablet
(crush tablet while still in packet) or granules
Note: You may hear a
buzzing sound from
the unit. This is normal
for start-up. Check for
leaks.
8. Close feed / close tank
9. Slowly crack open faucet
to depressurize the
system.
10. Allow system to
depressurize – leave faucet
open.
WARNING: Do
not open faucet all
the way. Air, water
and chemical
solution will spray
out forcefully. Be
prepared to
control the
anti–spray line.
should be closed.
be open.
(see page 5 of installation instructions)
Note: Do not over tighten.