K5 Drinking Water Station
Revised: 09/2016 Drinking Water Systems Section 7
Page 31
12. Wait 4 minutes
13. Close feed.
14. Close tank valve
Note: You may hear a
buzzing sound from the unit.
This is normal for
start-up.
15. Slowly open faucet to
depressurize the system.
16. Leave faucet open.
17. Remove cartridge plug.
WARNING: Do not
open faucet all the
way. Air, water
and chemical
solution will spray
out forcefully. Be
prepared to control
the anti-spray line.
WARNING: Handle plug with care when
removing. May contain chemical solution.
18. Pour one package of cleaning agent into dry cartridge plug
install plug into cartridge prefilter position.
19. Install RO.
Cleaning Agent: chlorine dioxide tablet
(crush tablet while still in packet) or
granules
prefilter position
20. Remove ⅜” plug from yellow port on manifold and insert ⅜”
tube into same port. Place other end into a 5 gallon bucket.
21. Slowly open feed valve.
Remove ⅜” plug from yellow port

Other manuals for Kinetico K5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kinetico K5 and is the answer not in the manual?

Kinetico K5 Specifications

General IconGeneral
Filter TypeReverse Osmosis
Daily Production Rate50 gallons per day
CertificationsNSF/ANSI 58
Filter Life6-12 months
Waste Water Ratio1:1

Related product manuals