4-25
REMOVING THE GAS DISTRIBUTION VALVE
1. Turn off gas supply and disconnect power
to the range.
WARNING
Electrical Shock Hazard
Disconnect power before
servicing.
Replace all parts and panels
before operating.
Failure to do so can result in
death or electrical shock.
Fire Hazard
Shut off gas supply line valve
before servicing.
Check all gas line connections
and replace all parts and panels
before operating.
Failure to do so can result in
explosion, fire or other injury.
2. Pull the range out of its mounting location
so that you can access the rear of the unit.
3. Remove the gas inlet and outlet lines from
the gas distribution valve.
4. Remove the two screws that mount the
gas distribution valve to the mounting
bracket and remove the valve.
Gas Distribution
Valve Screws
Inlet Line
Outlet Line
Bracket