PROBLEM POSSIBLE CAUSE / TEST
NOTE: Possible Cause/Tests MUST be performed
in the sequence shown for each problem.
WON’T POWER UP.
(No response when a
cycle button is pressed.)
1. Supply connection. See TEST #1.
2. Check harness connections.
3. User interface assembly. See TEST #5.
WON’T START CYCLE
WHEN START BUTTON
IS PRESSED.
1. If number display flashes, check to be sure the
door is completely shut, and press and hold
down Start for about 1 second.
2. See TEST #2.
3. See TEST #6.
WON’T SHUT OFF
WHEN EXPECTED.
1. Check Pause/Cancel button. See TEST #5.
2. User interface assembly. See TEST #5.
3. Moisture Sensor. See TEST #4.
CONTROL WON’T
ACCEPT SELECTIONS.
User interface assembly. See TEST #5.
WON’T HEAT.
1. Heater. See TEST #3.
2. Check harness connections.
3. Check installation.
HEATS IN AIR CYCLE.
Temperature sensor. See TEST #3a.
SHUTS OFF BEFORE
CLOTHES ARE DRY.
Moisture Sensor. See TEST #4.