Generator/Controller Troubleshooting 6-3TP-5648 8/93
Does engine
start?
Yes
No
Were glow
plugs
preheated?
No
Yes
Check 10A fuel
solenoid fuse in
controller wiring
harness. Is fuse
good?
Yes
No
Replace fuse.
Does trouble
repeat?
Rock Start/Stop
Switch to Stop
Position and hold
there for time given
in Section 2 to
preheat glow plugs.
Is 12 VDC present
at K25 contact
(wire 70A to GND)
with Start/Stop
Switch in Stop
Position?
Go to B
(Sheet 3)
A
(From
Sheet 1)
.
Is 12 VDC present
across fuel solenoid
(P5-4 to GND) with
Start/Stop Switch in
Start Position?
Yes
Engine fault.
(See Engine
Service
Manual)
No
Yes
Check/repair
wiring from P4-14
to P5-4.
Replace K25
relay.
.
Go to C
(Sheet 3)
.
Rock and hold
Start/Stop Switch
in Start Position.
Does engine start?
Yes
No
Does LED4 light
while Start/Stop
Switch is in Start
Position?
Replace circuit
board.
No
No
Trouble
corrected.
Fuse was
defective.
Yes
Yes
No
Check fuel
solenoid. Is fuel
solenoid good?
No
Replace fuel
solenoid.
Check wiring to
fuel solenoid for
shorts.
Yes
Figure 6-2. Troubleshooting Flow Chart (Sheet 2 of 4)