5-33
Accessory Troubleshooting
TP-5672 11/95
NOTE: Theammeterreadstheloadcurrent.Thesource
selectorswitchmustbeintheNORM. NA-NBL1
or L2 position to read the load current.
No
No
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
No
No
No
Yes
No
No
No
No
Does the ammeter display
load currents for L1 only?
Is the ratio of current that L1 is using
between terminals 12 and 21 of the
source selector switch correct? Refer
to Figure 5-35 for the proper turn ratio
of the current transformer.
Is the amount of current that L1 is
using between terminals 11 and 21
of the source selector switch correct?
Refer to Figure 5-35 for the proper
turn ratio of the current transformer.
Is the correct amount of current
load L1 is using between the
two terminals of the ammeter?
Are the leads from CT1
current transformer to
the source selector
switch open or shorted?
Is the amount of current that L2 is
using between terminals 13 and 21 of
the source selector switch correct?
Refer to Figure 5-35 for the proper
turn ratio of the current transformer.
Is the amount of current that L2 is
using between terminals 11 and 21
of the source selector switch correct?
Refer to Figure 5-35 for the proper
turn ratio of the current transformer.
Is the amount of current that L2
is using between the terminals of
the ammeter correct? Refer to
Figure 5-35 for the proper turn
ratio of the current transformer.
Are the leads from CT2
current transformer to the
source selector switch
open or shorted?
Replace the source
selector switch.
Replace the leads from source
selector switch to the
ammeter.
Replace the ammeter.
Replace the current
transformers.
Replace the leads from
the current transformer to
the source selector switch.
Replace the source
selector switch.
Replace the leads from source
selector switch to the ammeter.
Replace the ammeter.
Replace the current
transformers.
Replace the leads from
the current transformer to
the source selector switch.
Figure 5-39. TroubleshootingOption DD-18-J, Ammeter is not functioning