26
(6) Selection Knob (right)
For changing the arc length correction, welding voltage, and arc-force dynamic parameters
(7) Program Memory
This shows the working welding program memory.
(8) Voltage
This helps you to see the voltage or adjust it once required
(9) Pulse / arc-force dynamic correction
For continuously correcting the droplet detachment force in MIG/MAG pulsed
synergic welding
- ... reduced droplet detachment force
0 ... neutral droplet detachment force
+ ... increased droplet detachment force
For influencing the short-circuiting dynamic at the instant of droplet transfer in
MIG/MAG standard synergic welding, MIG/MAG standard manual welding, and
manual metal arc welding
- ... soft and low-spatter arc
0 ... neutral arc
+ ...harder and more stable arc
(10) Job selection
Synergic Job selection. The jobs can be selected from the Job List given on page 26
(11) Hold indicator
At the end of each welding operation, the actual values for welding current and
welding voltage are stored - the “HOLD” indicator lights up.
(12) Trigger operating mode selection
Enables 2T, 4T, S2T and S4T. For application refer to the page number 27
(13) Material type selection
For selecting the material used
(14) Wire diameter selection
For selecting the wire diameter used
(15) “Shielding gas” selection
For selecting the shielding gas used.
(16) “Process” selection **)
Enables Synergic, Pulse, Duo Pulse and Position for same JOB application
(17) Alternative quick Job selection
Enables XColds XRoot XDeep and XStabil for JOB application
NOTE!
The required brief information on the welding processes and the quick jobs as denoted by 16 and
17 above is given in this manual ahead on page numbers 38 and 39 respectively